In 1997, the ubc seismic provisions were revised from an allow. This part b compares the 1994 uniform building code requirements with those contained in the 1997 ubc, and provides design examples based on the 1997 ubc provisions. Seismic code requirements for anchorage of nonstructural components part b. A helpful map of the seismic zones in the united states, according to the ubc 1997 map. The four site coefficients s1 to s4 of the ubc 1994, which are independent of the level of ground shaking, were expanded to six soil profile types, which are dependent on the seismic zone factors, in the 1997 ubc sa to sf based on previous earthquake records.
Us ubc 1997 seismic zone map a helpful map of the seismic zones in the united states, according to the ubc 1997 map. Changes in ubc seismic base shear requirements for shearwall buildings in seismic zone 4 highest zone with an importance factor of 1. Nepsis equipment has been seismic qualified for placement. This variation can be easily observed in civil engineering as every project has different sets of characteristics despite of the fact that even if materials and requirements are taken as same. All of san diego county is located within seismic zone 4 sec. The example component is a package hvac unit mounted on the roof, with and without vibration isolators figure 1. Zoneii, iii, iv and v unlike its previous version which consisted of five zones for the country. Briefing paper 6 seismic code requirements for anchorage.
Seismic zone 4 map ca seismic zone map seismic zone map 2018 ibc seismic zones ubc 1997 seismic zone map seismic zone chart candysdirt childress engineering services zone map united states save map sone map eaton sseries nebs seismic rack enclosures. A stochasticevent probabilistic seismic hazard model, which can be used further for estimates of seismic loss and seismic risk analysis, has been developed for the territory of yemen. Structural observation required by building official seismic zones. Although you may hear the terms seismic zone and seismic hazard zone used interchangeably, they really describe two slightly different things. This code is often used as a reference in other african countries for seismic design provisions. The 2007, august 15 earthquake may be classified as mild for lima, and. Seismic code requirements for anchorage of nonstructural. Structural observation shall be provided for all structures in seismic zone 4 that require a lateral design and have an na factor as set forth in table 16s that is greater than one except for one and twostory buildings, housing group. For design base shear, v seismic e where, c v seismic coefficient depends upon soil profile. This paper presents a comparison of the seismic forces generated from a modal response spectrum analysis mrsa by applying the provisions of two building codes, the 1997 uniform building code ubc and the 20002009 international building code ibc, to the most common ordinary residential buildings of standard occupancy. Pdf comparison of egyptian code 2012 with eurocode 8. Also i m confused in excerpt from a document stating the special seismic load combination is also indirectly identified in chapter 18, section 1809, foundation construction seismic zones 3 and 4.
Structural observation shall be provided for all structures in seismic zone 4 that require a lateral design and have an na factor as set forth in table 16s that is greater than one except for one and twostory buildings, housing group b, f, m, s, r3 and u occupancies. The design base shear is depending on the seismic zone. The coefficient, and hence the expected ground accelerations are dependent on the seismic zone and soil profile type. Download uniform building code ubc 97 full pdf civil. Site specific geotechnical investigation and dynamic site response analysis must be performed. Need to know the most current ubc regulatory approvals.
Icbo continued to publish the updated versions of the code approx. New construction started after january 4,1993 federally owned, regulated or funded by federal loans, grants or loan guarantees building seismic safety council certifies model building codes for nehrp compliance icbo ubc uniform building code. Is there a more current ubc regulatory approval than ubc 1997. A comparative study with universal seismic codes a thesis submitted to university of khartoum in partial fulfillment for the degree of m. Pdf probabilistic seismic hazard analysis for yemen. Dead loads for ceiling joists, rafters, and floor joists are limited by the use of span tables. Whats the difference between seismic zone 4 maps and high. The seismic loading condition as specified in 1997 ubc, zone 4 was used.
International seismic zone tabulation proposed by the 1997 ubc uniform building code ubc97, uniform 1997 has introduced new provisions for the design of moc93 seismic zone map of mexico. Seismic zone is most important element in determining seismic forces. Now the question is how to determine seismic zone for some particular area. Factor which accounts for the ductility and overstrength of the structural system.
Wallace fall 04 1 ce243a 1 seismic code requirements john w. Structural observation required by building official seismic zones 3 and 4. The seismic zones map and seismic area map are generated using different criteria so no correlation can be drawn between the two maps, or seismic standards zone or areas derived by these maps. In seismic zones 3 and 4, structural observation should be provided and noted on the plans for high rises as defined in section 403, and for structures of occupancy category i, ii or iii as defined in table 16k. The assembly was analyzed to withstand the effects of seismic load combined with the static dead load of the assembly. Ubc defines some restrictions as per different zones, in 2b imrf minimum, and zone 3, 4 smrf. In other words, the earthquake zoning map of india divides india into 4 seismic zones zone 2, 3, 4 and 5 unlike its previous version, which consisted of five or six zones for the country. A seismic zone is used to describe an area where earthquakes tend to focus. According to 1997 ubc major changes from ubc 1994 1 soil profile types.
San francisco, ca 1997 ubc zone 4 d d d d denver, co 1997 ubc zone 1 a b b b c seattle, wa 1997 ubc zone 3 d d d d downtown, 4th and market streets. Table 3 provides a snapshot of the potential impact of the difference in seismic clas. United states seismic zones map sorth o kou bismarck soocb dakota pierre tex i. Seismic codes and standards plus design and installation instruction by. Seismic zone 4 related to both the proximity of the building or structure to known faults with magnitudes and slip rates as set forth in tables 16s and 16u.
Briefing paper 6 seismic code requirements for anchorage of. Structural systems according to ubc97 seismic design. Ghosh, design of reinforced concrete buildings under the 1997 ubc, building. In 1997, the ubc incorporated nearsource zones for calculating base shear, which.
Southern california is in zone 4 which is represented by. Standards are very important as far as engineering is concerned. The following sections are extracts of the ubc 1997. According to the present zoning map, zone 5 expects the highest level of seismicity whereas zone 2 is associated with the lowest level of seismicity. Seismic zone map of the united states icbo 1997, fig. The following is an example design calculation using the 1997 ubc. In the uniform building code ubc, the seismic zone in which a structure is located determines. W for an explanation of the terms used in the above equations, please refer to the ubc 1997 code. S austin ip, seismic zones ground acceleration d zone 0 o.
The value used for ct is user input and hn is determined from the level heights. Usually, in seismic zone 4, i dont design diaphragm exclusively. Nv nearsource factor used in the determination of cv in seismic zone 4 related to both the proximity of the building or structure to known faults with magnitudes. Considering ibc as the state of the art benchmark code. Zone 4 ubc or ibc requests can use netshelter sx cabinets.
An earlier version of the code was based on ubc but the most recent version is based on the draft env 1998. Instructional material complementing fema 451, design examples seismic load analysis 9 20 4 inplane discontinuity irregularity vertical structural irregularities d offset irregularity exists if the offset is greater than the width d or there exists a reduction in stiffness of the story below. In addition, for seismic zone 4, the total base shear shall also not be less than the following. Mar 09, 2017 ubc defines some restrictions as per different zones, in 2b imrf minimum, and zone 3, 4 smrf. Nebs level 3 zone 4 compliance testing per telcordia technologies gr63 core is not recognized by the icc or asce 7. An updated code has been in development since 20 but the authors were unable to obtain. Nv nearsource factor used in the determination of cv in seismic zone 4 related to both the proximity of the building or. Seismic qualified equipment eddie wilkie engineering manager power distribution organization americas. This paper presents comparative study for seismic provisions of four building codes egyptian code for loads ecl 2012, eurocode 820, ibc 2015 and ubc 1997 to the prevailing multistory. Download uniform building code ubc 97 full pdf civil engineering codes by. Equation 307 in addition, for seismic zone 4, the total base shear shall also not be less than v 0. Us ubc 1997 seismic zone map partner engineering and. Eliminating the confusion from seismic codes and standards. Comparison of the seismic provisions of the 1997 uniform.
The building is on soil profile sd in seismic zone 4 and is not in a nearsource location i. Code 1997 ubc and international building code 2006 ibc. Recommended seismic provisions for new buildings and other structures. In recent editions of the uniform building code ubc, the u. The period is calculated using equation 21 1997 ubc equation 308. Interactive map of earthquakes in montana american geosciences. The seismic coefficients, cv and ca are measures of the expected ground acceleration at the site. There are two stages of command specification for generating lateral loads. Aug 20, 2014 home books download uniform building code ubc 97 full pdf civil engineering codes.
The seismic zone factor zone in conjunction with the soil profile type styp, near source factor na, and the near source factor nv, is used to determine the values of seismic coefficients ca and cv from tables 16q and 16r of the ubc 1997 code. For a complete explanation of seismic compliance for netshelter products please see knowledge base documents fa232050 and fa239257. Although the 1997 usc seismic zone only considers the seismicity of a location whereas the 1997 nehrp seismic design category takes into account the building occupancy and soil type as well as seismicity, an equivalency between seismic zone and seismic design category was assumed for this comparison study. Whatever we do, whatever we perform we follow a standard or we try our level best to meet that standard in order to ensure quality. Home resources library us ubc 1997 seismic zone map. Is there a more current ubc regulatory approval than ubc.
Ubc 97 defines seismic zones for usa in figure 162. The building period, t, that the programs choose depends on the seismic zone factor, z. Nv nearsource factor used in the determination of cv in. A comparison of ibc with 1997 ubc for modal response. Frame construction manual for one and twofamily dwellings. In seismic zone 4 total loads exceeding those prescribed in certain span tables require an engineered lateralforceresisting system. Typically, a high seismic hazard zone is nearest a seismic zone where there are more earthquakes, and a. A seismic hazard zone describes an area with a particular level of hazard due to. A seismic hazard zone describes an area with a particular level of hazard due to earthquakes. The tank appendages and tank bracing, constructed of structural steel, were evaluated such. Design and analysis of pressure vessel skirt considering. The 1973 uniform building code ubc, 1973 included northern new.
Figure 1 hazard curves for selected cities nehrp 1997. They may be found in tables 16q and tables 16r of ubc code see image below respectively. International building code f a and f v decrease with the increase of seismic hazard on rock due to soil. Download uniform building code ubc 97 full pdf civil engineering codes.
834 795 1057 260 177 1123 1399 187 1112 1595 607 1603 744 788 853 1507 1340 870 1645 1064 93 1611 771 278 184 1357 414 1494 237 854 67 65 696 417 1487 17 868 1443